Tuesday, February 28, 2017

The basis for dividing the space

1, on the space of the knowledge Please see the forum "interior space design" related topics, repeat things here do not speak, we focus on the type of space and space performance aspects of knowledge, which will be on this helpful.
2, from today we will draw on the building of the building plan according to the requirements of the requirements of a division, please own according to the plan I provide a division, and then you divided the results of the reply to pay up as today The operation.

3, the basis for spatial division:
First, the function, that is, the functional requirements of Party A.
Here we first have to break down the function to see what these features inside the small segment of the small function, which is very important for the division of space, the following I will explain the specific functional requirements:
1, the first floor of the hall, the purpose of the whole building is to bath as the core, that bath is the main design of the main line, the design of the lobby should be from this point of view. The lobby function should meet the following features
    (1) reception function, the reception function is reflected in the hall must have a large bar, and the lobby manager's location (usually in a place to place a table)
    (2) the settlement function, all the settlement should be carried out in the foreground, so here is the center of the entire financial system
    (3) for shoes and save the shoes of the function, all the visitors have to change shoes here, so the lobby to set the shoe and save the shoe area, change the shoes area is best to have a separate semi-private space form
    (4) shunt function, the guests of the bath there are men and women of the points, the guests come after the visual and spatial division of the individual on a clear orientation
    (5) to express the corporate image of the function, which should be the main design style, later talk about.
2, male bath area male bath area is the man bath space, it is divided into two parts of the dry and wet areas, the so-called dry area refers to the locker room part, wet area refers to the bath space
    (1) dressing room men in the hall for shoes, and then into the dressing area, changing clothes in the dressing area, here is the first step into the men and women, but also men out of the settlement before the last link. Dressing room main furniture with wardrobe (2100 high, 550 * 350), towel rack, dressing table and make-up mirror (by import and export, for guests after changing clothes), requires the design of 300 people.
    (2) Take bath area Wet area This section has the following breakdown function
    1) bathroom design requirements of two to three, built-in squatting three and two urinals, the location near the entrance in the wet area, to facilitate visitors before the bath to deal with the size of matters.
    2) shower design requirements of about 15, each shower occupies the space size of 1100 * 1000
    3) bath area of ​​its relevant space size can refer to the books, set about 3 - 5 nozzle
    4) rubbing bath area bathing bed size 700 * 1900, the space may be, not less than 8 beds, according to the modern habits and psychological requirements, the best bathing area is relatively independent, the distance between the bathing bath Allow a person to pass freely, each bed (or two beds) next to a faucet (hot and cold water), do bath with a spare platform.
    5) hot water temperature of more than 34 degrees, who volume about 3 cubic meters
    6) cold pool capacity requirements ibid.
    7) warm pool capacity requirements of about 15 cubic meters, the depth of the pool 900, including the ground step part.
    8) a sauna, an area of ​​about 20 square meters, next to an external control room, about 2 square meters
    9) the second dressing area guests after bathing bathrobe in this area, and a simple make-up, where you should set the bathrobe showcase, a small rest area (tea), dressing table, located near the exit, the space is relatively closed
    The above is the main functional area, of course, according to the size of the space appropriate to increase or decrease the subtle function
(2) the line design line for the functional areas of the flow of personnel, the division of the space first design flow routes, design flow routes should be understood from the functional requirements of a reasonable route, generally in a layer of the rational flow of the guests is the way
    Go to the hall (change shoes, take the key) - into the locker room (undress) - bath - the second dressing - into the second floor above the service area - back to enter the bath area - bath - locker room dress - - Hall settlement - go out
    Design of the line should also consider the width of the aisle and the size of the door, which should be based on the design of the guests based on the same time to consider the requirements of fire evacuation, do the case of each functional area between the door is not less than 1500 wide, Requires two people to pass at the same time.
    It is recommended that the above mentioned functional areas are set on the first floor of the area.
(3) plane division and graphic design
    Some people put the layout of the plane layout and graphic design and color design linked together, that is, according to the plane (advertising plane) to design the layout of the plan, that the plan to see the space division of the reasonable, this idea is Wrong, I would like to remind you here, the space is four-dimensional, that is only in the flow of observation space to reflect the rationality of space (including the design of the line).